<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"><channel><title>SPLIDIA — Operational notes</title><description>Field guides on optical fibre splicing and certification, networks, IT and AI applied to infrastructure.</description><link>https://splidia.com/</link><language>en</language><item><title>SINFI 4.0 and network nodes: one boolean for cyber vulnerability, one for early warning</title><link>https://splidia.com/en/notes/nodi-rete-catasto-amplificatori-vulnerabilita/</link><guid isPermaLink="true">https://splidia.com/en/notes/nodi-rete-catasto-amplificatori-vulnerabilita/</guid><description>Network nodes in SINFI 4.0: amplifiers, monitoring, electricity users. For class ND_COM these are proposals still to be agreed, not obligations.</description><pubDate>Wed, 29 Jul 2026 00:00:00 GMT</pubDate></item><item><title>Testing multifibre links: loss is not enough, end-face geometry decides</title><link>https://splidia.com/en/notes/geometria-faccia-ferrula-multifibra/</link><guid isPermaLink="true">https://splidia.com/en/notes/geometria-faccia-ferrula-multifibra/</guid><description>IEC 61300-3-30:2026: end-face geometry of rectangular ferrules, x116 and x132 regions, tables for 16, 24 and 32 fibres. What to put in the specification.</description><pubDate>Wed, 29 Jul 2026 00:00:00 GMT</pubDate></item><item><title>B2ca vs Cca vs Dca vs Eca: which cable class do you actually need?</title><link>https://splidia.com/en/notes/b2ca-cca-dca-eca-quale-classe-serve/</link><guid isPermaLink="true">https://splidia.com/en/notes/b2ca-cca-dca-eca-quale-classe-serve/</guid><description>B2ca or Cca? Cca or Dca? What really separates the CPR cable classes, who sets the minimum class, and how to check it on the DoP.</description><pubDate>Wed, 29 Jul 2026 00:00:00 GMT</pubDate></item><item><title>The closure is IP68. But does it actually seal, and after how many re-entries?</title><link>https://splidia.com/en/notes/muffole-giunzione-tenuta-ip68-collaudo/</link><guid isPermaLink="true">https://splidia.com/en/notes/muffole-giunzione-tenuta-ip68-collaudo/</guid><description>Fibre splice closures: what the IP68 rating does not say, which tests really qualify a closure under ITU-T L.201 and IEC 61753, and what to demand in the specification.</description><pubDate>Tue, 28 Jul 2026 00:00:00 GMT</pubDate></item><item><title>SINFI 4.0: “optical fibre” is no longer enough for Italy’s network cadastre</title><link>https://splidia.com/en/notes/sinfi-specifiche-4-0-catasto-fibra/</link><guid isPermaLink="true">https://splidia.com/en/notes/sinfi-specifiche-4-0-catasto-fibra/</guid><description>SINFI specification 4.0, AgID determination 129/2026: transmission medium now mandatory to ITU-T, new subsea classes, status attribute. What to record on site.</description><pubDate>Tue, 28 Jul 2026 00:00:00 GMT</pubDate></item><item><title>Can you run an OTDR on a live fibre without taking the customer down?</title><link>https://splidia.com/en/notes/misura-fibra-in-esercizio-1650-nm/</link><guid isPermaLink="true">https://splidia.com/en/notes/misura-fibra-in-esercizio-1650-nm/</guid><description>In-service testing: the 1650 nm maintenance band, the cut-off filter at the user end, and the ITU-T L.313 (ex L.66) requirements for your specification.</description><pubDate>Tue, 28 Jul 2026 00:00:00 GMT</pubDate></item><item><title>Data centres in Italy: what to attach to the single authorisation application</title><link>https://splidia.com/en/notes/data-center-pucd-cosa-allegare-istanza/</link><guid isPermaLink="true">https://splidia.com/en/notes/data-center-pucd-cosa-allegare-istanza/</guid><description>The first MASE operational guidance on the PUCD: assessment fees paid by two separate transfers, planning conformity, grid works and when the clock restarts.</description><pubDate>Mon, 27 Jul 2026 00:00:00 GMT</pubDate></item><item><title>Which technologies reach your address? Your provider now has to tell you</title><link>https://splidia.com/en/notes/tecnologie-disponibili-indirizzo-obbligo-informativo/</link><guid isPermaLink="true">https://splidia.com/en/notes/tecnologie-disponibili-indirizzo-obbligo-informativo/</guid><description>Article 13(1)(b) of decree-law 19/2026: technologies available at the address must be disclosed to consumers. AGCOM reads it as covering rival operators.</description><pubDate>Mon, 27 Jul 2026 00:00:00 GMT</pubDate></item><item><title>Fibre connections up to forty metres: eight days’ notice by certified email and the site opens</title><link>https://splidia.com/en/notes/allaccio-utenza-quaranta-metri-preavviso-pec/</link><guid isPermaLink="true">https://splidia.com/en/notes/allaccio-utenza-quaranta-metri-preavviso-pec/</guid><description>Article 49, paragraphs 7-bis and 7-ter of the Italian code: ultra-broadband customer connections up to forty metres need one certified email, eight days ahead.</description><pubDate>Mon, 27 Jul 2026 00:00:00 GMT</pubDate></item><item><title>New builds and renovations: fibre has been mandatory since 12 February 2026</title><link>https://splidia.com/en/notes/fibra-obbligatoria-edifici-nuovi-12-febbraio-2026/</link><guid isPermaLink="true">https://splidia.com/en/notes/fibra-obbligatoria-edifici-nuovi-12-febbraio-2026/</guid><description>Regulation (EU) 2024/1309, Article 10: new buildings and major renovations must be fibre-equipped. Who is bound, which exemptions apply, what to specify.</description><pubDate>Sun, 26 Jul 2026 00:00:00 GMT</pubDate></item><item><title>Is it dangerous to look into an optical fibre? It depends on what is upstream</title><link>https://splidia.com/en/notes/sicurezza-laser-fibra-ottica-obblighi/</link><guid isPermaLink="true">https://splidia.com/en/notes/sicurezza-laser-fibra-ottica-obblighi/</guid><description>Laser safety on fibre networks: IEC 60825-1 and 60825-2, hazard levels at each accessible location, and the duties and penalties of Italy’s d.lgs. 81/2008.</description><pubDate>Sun, 26 Jul 2026 00:00:00 GMT</pubDate></item><item><title>Which one is fibre 7 in this cable? It depends on the colour code you are using</title><link>https://splidia.com/en/notes/codici-colore-fibre-tubetti-cavo-ottico/</link><guid isPermaLink="true">https://splidia.com/en/notes/codici-colore-fibre-tubetti-cavo-ottico/</guid><description>Fibre and buffer tube colour codes: why no universal scheme exists, what IEC TR 63194 and TIA-598 say, and what to demand in the specification and the as-built.</description><pubDate>Sun, 26 Jul 2026 00:00:00 GMT</pubDate></item><item><title>Why does a brand-new fibre link fail its test? Look at the connector end face</title><link>https://splidia.com/en/notes/ispezione-pulizia-faccia-connettori-ottici/</link><guid isPermaLink="true">https://splidia.com/en/notes/ispezione-pulizia-faccia-connettori-ottici/</guid><description>Contaminated connector end faces: what IEC 61300-3-35:2022 asks for, why loss and reflectance fail together, and what to demand in the specification.</description><pubDate>Sat, 25 Jul 2026 00:00:00 GMT</pubDate></item><item><title>Duct installation: what is the maximum pulling tension on an optical fibre cable?</title><link>https://splidia.com/en/notes/tiro-massimo-cavo-fibra-cavidotto/</link><guid isPermaLink="true">https://splidia.com/en/notes/tiro-massimo-cavo-fibra-cavidotto/</guid><description>ITU-T L.100 sets the pulling rating at 1.5 times the weight of 1 km of cable, capped at 2700 N: bend diameters, lubricant and when blowing is better.</description><pubDate>Sat, 25 Jul 2026 00:00:00 GMT</pubDate></item><item><title>Will the fibre you already have take the step up to 100G and 400G?</title><link>https://splidia.com/en/notes/cd-pmd-fibra-esistente-100g-400g/</link><guid isPermaLink="true">https://splidia.com/en/notes/cd-pmd-fibra-esistente-100g-400g/</guid><description>Chromatic dispersion and PMD on existing runs: what coherent transceivers change, what to measure before deciding, and what to put in the specification.</description><pubDate>Sat, 25 Jul 2026 00:00:00 GMT</pubDate></item><item><title>Data centres of national strategic interest: the Government commissioner</title><link>https://splidia.com/en/notes/data-center-interesse-strategico-nazionale/</link><guid isPermaLink="true">https://splidia.com/en/notes/data-center-interesse-strategico-nazionale/</guid><description>Italy declares Equinix and Cavour Hyperscale Campus of national strategic interest: how the Government commissioner works and what to check before you bid.</description><pubDate>Fri, 24 Jul 2026 00:00:00 GMT</pubDate></item><item><title>DWDM or CWDM: which ITU-T grid to link two company sites?</title><link>https://splidia.com/en/notes/dwdm-cwdm-interconnessione-sedi-aziendali/</link><guid isPermaLink="true">https://splidia.com/en/notes/dwdm-cwdm-interconnessione-sedi-aziendali/</guid><description>The ITU-T G.694.1 (DWDM) and G.694.2 (CWDM) grids: channels, spacing, and why the multiplexer&apos;s loss threshold is set by the specification, not the standard.</description><pubDate>Fri, 24 Jul 2026 00:00:00 GMT</pubDate></item><item><title>OTDR dead zones: how to choose the pulse width and stop losing events</title><link>https://splidia.com/en/notes/zone-morte-otdr-scelta-impulso/</link><guid isPermaLink="true">https://splidia.com/en/notes/zone-morte-otdr-scelta-impulso/</guid><description>Event and attenuation dead zones, pulse width converted into metres, launch fibres of 1-2 km: how an OTDR is set up and what to write into the specification.</description><pubDate>Fri, 24 Jul 2026 00:00:00 GMT</pubDate></item><item><title>Cybersecurity Act: high-risk vendors out of the network</title><link>https://splidia.com/en/notes/cybersecurity-act-fornitori-alto-rischio/</link><guid isPermaLink="true">https://splidia.com/en/notes/cybersecurity-act-fornitori-alto-rischio/</guid><description>The revised Cybersecurity Act aims to remove Huawei and ZTE from European networks within three years: the real GSMA figures and what to check in tenders.</description><pubDate>Thu, 23 Jul 2026 00:00:00 GMT</pubDate></item><item><title>Eca, Cca, B2ca: what the CPR says, and what to put in the spec</title><link>https://splidia.com/en/notes/cavi-cpr-classe-fuoco-capitolato/</link><guid isPermaLink="true">https://splidia.com/en/notes/cavi-cpr-classe-fuoco-capitolato/</guid><description>EU Regulation 305/2011 (CPR): the seven fire-reaction classes for cables, real FIGRA and THR values, smoke, droplets, acidity, and what to put in the spec.</description><pubDate>Thu, 23 Jul 2026 00:00:00 GMT</pubDate></item><item><title>How many dB does a PON splitter lose? The ITU-T G.671 thresholds</title><link>https://splidia.com/en/notes/splitter-pon-perdita-inserzione-odn/</link><guid isPermaLink="true">https://splidia.com/en/notes/splitter-pon-perdita-inserzione-odn/</guid><description>The ITU-T G.671 (11/2025) tables on insertion loss for PON splitters 1:8, 1:16, 1:32 and 1:64: the right values for optical budget and ODN specifications.</description><pubDate>Thu, 23 Jul 2026 00:00:00 GMT</pubDate></item><item><title>How Do You Calculate the Optical Budget of a Fibre Link?</title><link>https://splidia.com/en/notes/budget-ottico-calcolo-tratta-fibra/</link><guid isPermaLink="true">https://splidia.com/en/notes/budget-ottico-calcolo-tratta-fibra/</guid><description>The optical budget decides whether a fibre link passes testing: the formula, attenuation values, connectors, splices and the right design margin.</description><pubDate>Wed, 22 Jul 2026 00:00:00 GMT</pubDate></item><item><title>Data centres: a single permit, but the 90-day window will not wait</title><link>https://splidia.com/en/notes/data-center-autorizzazione-unica-90-giorni/</link><guid isPermaLink="true">https://splidia.com/en/notes/data-center-autorizzazione-unica-90-giorni/</guid><description>MASE publishes the first rules for the single data-centre permit: a ten-month procedure, but a peremptory 90-day window for the EIA dossier after the STMG.</description><pubDate>Wed, 22 Jul 2026 00:00:00 GMT</pubDate></item><item><title>G.652 or G.657: Which Fibre to Specify for Tight Bends?</title><link>https://splidia.com/en/notes/g652-g657-raggio-curvatura-fibra/</link><guid isPermaLink="true">https://splidia.com/en/notes/g652-g657-raggio-curvatura-fibra/</guid><description>G.652.D and G.657 A1/A2/B2/B3: minimum bend radii, macrobend loss values in dB and what to specify for dense patch panels, racks and building entries.</description><pubDate>Wed, 22 Jul 2026 00:00:00 GMT</pubDate></item><item><title>A Fibre Network Without As-Built Records Is an Asset No One Can Read Anymore.</title><link>https://splidia.com/en/notes/as-built-etichettatura-catasto-fibra/</link><guid isPermaLink="true">https://splidia.com/en/notes/as-built-etichettatura-catasto-fibra/</guid><description>As-built records, labelling and the fibre asset register: how network documentation cuts fault-repair times and sets the real value of the infrastructure.</description><pubDate>Tue, 21 Jul 2026 00:00:00 GMT</pubDate></item><item><title>Digital Networks Act: Copper Switches Off Area by Area, Not on One Date</title><link>https://splidia.com/en/notes/digital-networks-act-spegnimento-rame/</link><guid isPermaLink="true">https://splidia.com/en/notes/digital-networks-act-spegnimento-rame/</guid><description>The Digital Networks Act sets 2035 as the threshold for switching off copper, not a single deadline: what changes today for specs and migrations in Italy.</description><pubDate>Tue, 21 Jul 2026 00:00:00 GMT</pubDate></item><item><title>Fibre-Optic Tapping: the Risk Sits in the Splice, Not in the Cable.</title><link>https://splidia.com/en/notes/intercettazione-fibra-ottica-rischi-reali/</link><guid isPermaLink="true">https://splidia.com/en/notes/intercettazione-fibra-ottica-rischi-reali/</guid><description>Fibre tapping, bend couplers, unattended splice closures: how an optical fibre is actually tapped, and how to detect it before it becomes a problem.</description><pubDate>Tue, 21 Jul 2026 00:00:00 GMT</pubDate></item><item><title>Fibre on the factory floor: why plant networks are not office networks</title><link>https://splidia.com/en/notes/fibra-reti-industriali-ambienti-ostili/</link><guid isPermaLink="true">https://splidia.com/en/notes/fibra-reti-industriali-ambienti-ostili/</guid><description>Electromagnetic immunity, redundant rings, hostile-environment installation: why fibre, not copper, is the standard for industrial networks and Industry 4.0.</description><pubDate>Mon, 20 Jul 2026 00:00:00 GMT</pubDate></item><item><title>Micro-trenching and mini-trenching: fast fibre laying still follows strict rules.</title><link>https://splidia.com/en/notes/microtrincea-minitrincea-permessi-ripristino/</link><guid isPermaLink="true">https://splidia.com/en/notes/microtrincea-minitrincea-permessi-ripristino/</guid><description>Micro-trenching and mini-trenching for fibre optics: what the 2013 excavation decree says, which permits are required, and how road reinstatement works.</description><pubDate>Mon, 20 Jul 2026 00:00:00 GMT</pubDate></item><item><title>Heading to 800G: Projects Fail on the Cabling, Not the Technology</title><link>https://splidia.com/en/notes/om4-om5-800g-cablaggio-data-center/</link><guid isPermaLink="true">https://splidia.com/en/notes/om4-om5-800g-cablaggio-data-center/</guid><description>In 2026 data centres move from 400G to 800G: OM4, OM5, 8, 12 or 16-fibre MPO. Speed is set by the transceivers, but the project is made by the fibre.</description><pubDate>Mon, 20 Jul 2026 00:00:00 GMT</pubDate></item><item><title>Severed Submarine Cables: Network Resilience Is Physical</title><link>https://splidia.com/en/notes/cavi-sottomarini-resilienza-reti/</link><guid isPermaLink="true">https://splidia.com/en/notes/cavi-sottomarini-resilienza-reti/</guid><description>Anchors severing cables in the Baltic and the Red Sea, and the EU&apos;s plan for cable security: why real redundancy is engineered into trenches, not routers.</description><pubDate>Sun, 19 Jul 2026 00:00:00 GMT</pubDate></item><item><title>EN 50600: the four availability classes for a data centre, in practice</title><link>https://splidia.com/en/notes/en-50600-sale-dati-aziendali/</link><guid isPermaLink="true">https://splidia.com/en/notes/en-50600-sale-dati-aziendali/</guid><description>What the EN 50600 series actually requires: availability classes 1 to 4, redundant pathways, cabling to EN 50173/50174, and what to put in the specification.</description><pubDate>Sun, 19 Jul 2026 00:00:00 GMT</pubDate></item><item><title>GPON or XGS-PON: Symmetrical 10-Gigabit Fibre Has Arrived — Is Your Site Ready?</title><link>https://splidia.com/en/notes/gpon-xgs-pon-10-giga-in-azienda/</link><guid isPermaLink="true">https://splidia.com/en/notes/gpon-xgs-pon-10-giga-in-azienda/</guid><description>XGS-PON delivers symmetrical 10 Gbit/s on the same fibre: what changes compared with GPON, when it is worth it, and why the bottleneck is internal cabling.</description><pubDate>Sun, 19 Jul 2026 00:00:00 GMT</pubDate></item><item><title>Italy&apos;s data centre boom: €25 billion, and every megawatt means fibre</title><link>https://splidia.com/en/notes/boom-data-center-italia-cablaggio/</link><guid isPermaLink="true">https://splidia.com/en/notes/boom-data-center-italia-cablaggio/</guid><description>Record investment in Italian data centres: Milan heading towards 1 GW, double-digit growth driven by AI. What changes for those who build, cable and connect.</description><pubDate>Sat, 18 Jul 2026 00:00:00 GMT</pubDate></item><item><title>Italy 1 Gigabit Plan: Deadline Passed, What Changes for Businesses</title><link>https://splidia.com/en/notes/piano-italia-1-giga-dopo-giugno-2026/</link><guid isPermaLink="true">https://splidia.com/en/notes/piano-italia-1-giga-dopo-giugno-2026/</guid><description>June 2026 was the PNRR ultra-broadband deadline: 700,000 addresses deferred to 2030, new tenders and mixed technologies. What to do if you are out.</description><pubDate>Sat, 18 Jul 2026 00:00:00 GMT</pubDate></item><item><title>OTDR Certification: How to Actually Read a Test Report</title><link>https://splidia.com/en/notes/certificazione-otdr-come-leggere-report/</link><guid isPermaLink="true">https://splidia.com/en/notes/certificazione-otdr-come-leggere-report/</guid><description>Tier 1 and tier 2, dead zones, bidirectional measurement: how to read an OTDR report, spot a poorly executed test, and what to ask whoever hands it to you.</description><pubDate>Fri, 17 Jul 2026 00:00:00 GMT</pubDate></item><item><title>Fusion or mechanical splicing: what to put in the spec</title><link>https://splidia.com/en/notes/giunzione-fusione-o-meccanica/</link><guid isPermaLink="true">https://splidia.com/en/notes/giunzione-fusione-o-meccanica/</guid><description>Fusion versus mechanical splicing: typical loss, reflectance and lifespan compared, when mechanical makes sense, and which values to demand in the spec.</description><pubDate>Fri, 10 Jul 2026 00:00:00 GMT</pubDate></item></channel></rss>